AVK FABRICATED FLANGE ADAPTOR, PN16
For CI, DI, imp. PVC/STEEL, PVC pipes, fasteners zinc plated and passivated, coating 250 µm
Contact
AVK International A/S
Bizonvej 1, Skovby, 8464 Galten, Denmark
Flange adaptor for CI, DI, imp. PVC/STEEL, PVC pipes, PN16. Maximum Working Pressure: 16 Bar, to -0.8 Bar (negative pressure). Temperature Range: -10°C to +70°C, Insulation essential for temperatures of 0°C and below
The Series 260 is a fabricated flange adaptor, suitable for use with water and neutral liquids (sewage). To suit all pipe types including ferrous, GRP, UPVC, AC and stainless steel pipes / welded tube.
Variant 260/30-022 | |
---|---|
Connection: | Mechanical Joint x Flange |
Material: | Steel |
DN: | DN350 - DN1600 |
PN: | PN16 |
Features
- EPDM seals
- Corrosion resistant construction
- Can be fabricated in any size within design range of DN250 to DN1600+
- Coating options: Scotchcote, Black. Coating thickness 300 & 500µ
- Fusion bonded epoxy coating to WIS 4-52-01
- Zinc plated and passivated stud sets
- Sealing range nominal diameter +2mm to -5mm
- Angular deflection:
- < than DN600 is ± 4°
- DN700 to DN800 is ± 3°
- DN900 to DN1200 is ± 2°
Downloads
Datasheet
Installation, Operation & Maintenance
Reference nos. and dimensions:
Scroll for more info
AVK ref. no. | DN mm |
H3 mm |
L mm |
L5 mm |
Pipe dia. mm |
Bolt No. |
Pipe Type |
Theoretical weight/kg |
Notes |
---|---|---|---|---|---|---|---|---|---|
260-30-0355-1000 | 350 | 505 | 178 | 25 | 355 | 16 | PVC/ST | 33 | |
260-30-0378-1000 | 350 | 505 | 178 | 25 | 378 | 16 | DI | 33 | |
260-30-0387-1000 | 350 | 505 | 178 | 25 | 387 | 16 | CI | 33 | |
260-30-0399-1000 | 350 | 505 | 178 | 25 | 399 | 16 | CI | 34 | Internal steeping in the body that will limit the insertion of the pipe, consult AVK if this is to be removed |
260-30-0400-1002 | 400 | 565 | 178 | 25 | 400 | 16 | PVCM | 38 | |
260-30-0406-1002 | 400 | 565 | 178 | 25 | 406 | 16 | PVC/ST | 38 | |
260-30-0429-1002 | 400 | 565 | 178 | 25 | 429 | 16 | DI | 38 | |
260-30-0439-1002 | 400 | 565 | 178 | 25 | 439 | 16 | CI | 39 | |
260-30-0450-1003 | 450 | 615 | 178 | 25 | 450 | 20 | PVCM | 42 | |
260-30-0453-1003 | 450 | 615 | 178 | 25 | 453 | 20 | CI | 42 | |
260-30-0457-1003 | 450 | 615 | 178 | 25 | 457 | 20 | PVC/ST | 43 | |
260-30-0480-1003 | 450 | 615 | 255 | 25 | 480 | 20 | DI | 59 | |
260-30-0492-1003 | 450 | 615 | 178 | 25 | 492 | 20 | CI | 60 | |
260-30-0500-1004 | 500 | 670 | 178 | 25 | 500 | 20 | PVCM | 46 | |
260-30-0507-1003 | 450 | 615 | 178 | 25 | 507 | 20 | CI | 63 | |
260-30-0508-1004 | 500 | 670 | 178 | 25 | 508 | 20 | PVC/ST | 46 | |
260-30-0532-1004 | 500 | 670 | 178 | 25 | 532 | 20 | DI | 47 | |
260-30-0545-1004 | 500 | 670 | 178 | 25 | 545 | 20 | CI | 64 | |
260-30-0560-1004 | 500 | 670 | 178 | 25 | 560 | 20 | PVCM/CI | 65 | |
260-30-0609-1004 | 500 | 670 | 178 | 25 | 609 | 20 | PVC/ST | 78 | Internal steeping in the body that will limit the insertion of the pipe, consult AVK if this is to be removed |
260-30-0630-1005 | 600 | 780 | 178 | 25 | 630 | 20 | PVCM | 57 | |
260-30-0635-1005 | 600 | 780 | 178 | 25 | 635 | 20 | DI | 57 | |
260-30-0650-1005 | 600 | 780 | 178 | 25 | 650 | 20 | CI | 57 | |
260-30-0667-1005 | 600 | 780 | 178 | 25 | 667 | 20 | CI | 57 | Internal steeping in the body that will limit the insertion of the pipe, consult AVK if this is to be removed |
260-30-0710-1006 | 700 | 895 | 178 | 25 | 710 | 24 | PVCM | 68 | |
260-30-0711-1006 | 700 | 895 | 178 | 25 | 711 | 24 | PVC/ST | 68 | |
260-30-0729-1006 | 700 | 895 | 178 | 25 | 729 | 24 | CI | 69 | |
260-30-0738-1006 | 700 | 895 | 178 | 25 | 738 | 24 | DI | 69 | |
260-30-0747-1006 | 700 | 895 | 178 | 25 | 747 | 24 | CI | 69 | |
260-30-0807-1007 | 800 | 1025 | 178 | 25 | 807 | 24 | CI | 83 | |
260-30-0812-1007 | 800 | 1025 | 178 | 25 | 812 | 24 | PVC/ST | 83 | |
260-30-0826-1007 | 800 | 1025 | 178 | 25 | 826 | 24 | CI | 83 | |
260-30-0842-1007 | 800 | 1015 | 178 | 25 | 842 | 24 | DI | 84 | |
260-30-0914-1008 | 900 | 1115 | 178 | 25 | 914 | 28 | PVC/ST | 94 | |
260-30-0945-1008 | 900 | 1125 | 178 | 25 | 945 | 28 | DI | 92 | |
260-30-0964-1008 | 900 | 1115 | 178 | 25 | 964 | 28 | CI | 91 | |
260-30-0985-1008 | 900 | 1115 | 178 | 25 | 985 | 28 | CI | 92 | |
260-30-1016-1009 | 1000 | 1255 | 198 | 30 | 1016 | 28 | PVC/ST | 127 | |
260-30-1048-1009 | 1000 | 1255 | 198 | 30 | 1048 | 28 | DI | 128 | |
260-30-1121-1009 | 1000 | 1255 | 288 | 30 | 1121 | 28 | CI | 145 | Internal steeping in the body that will limit the insertion of the pipe, consult AVK if this is to be removed |
260-30-1143-1009 | 1000 | 1255 | 288 | 30 | 1143 | 28 | CI | 147 | Internal steeping in the body that will limit the insertion of the pipe, consult AVK if this is to be removed |
260-30-1220-1011 | 1200 | 1485 | 198 | 30 | 1220 | 32 | PVC/ST | 162 | |
260-30-1255-1011 | 1200 | 1455 | 198 | 30 | 1255 | 32 | DI | 163 | |
260-30-1277-1011 | 1200 | 1455 | 198 | 30 | 1277 | 32 | CI | 180 | |
260-30-1600-1017 | 1600 | 1930 | 263 | 35 | 1600 | 40 | DI | 270 |
2D/3D drawings
Enquiry
Scroll for more info
Components
1. | Body | Steel S275JR |
2. | Gland ring | Steel S275JR |
3. | Seal | EPDM rubber |
4. | Studs | Steel gr. 8.8, zinc plated, passivated |
5. | Washer | Steel gr. 8.8, zinc plated, passivated |
6. | Nuts | Steel gr. 8.8, zinc plated, passivated |
Test/Approvals
- Hydraulic test: 1.5 x PN
- Belgaqua approved
- WRAS approved materials
Standards
- Standard flange drilling to EN1092-2 (ISO 7005-2), PN16